BELDEN 5304FE
BELDEN 5304FE

BELDEN 5304FE

Price 120 INR/ Meter

BELDEN 5304FE Specification

  • Core Material
  • Polyolefin-Insulated Copper
  • Cable Type
  • Multi-Conductor
  • Rated Temperature
  • 60°C
  • Install Type
  • Plenum
  • Armored Material
  • Not Armored
  • Weight
  • Approx. 39 Lbs/1000 Ft
  • Features
  • Flame Retardant, Flexible, High Performance, Low Smoke, Signal Transmission, UV Resistant, Plenum Rated
  • Conductor Shape
  • Round
  • Usage & Applications
  • Fire and Security Systems, Instrumentation, Low-Voltage Control
  • Conductor Type
  • Solid
  • Operating Temperature
  • -20°C to +60°C
  • Number of Conductor
  • 4
  • Insulation
  • Polyolefin
  • Diameter
  • 0.162 inch (4.11mm)
  • Core Number
  • 4
  • Product Type
  • Low Voltage Data/Control Cable
  • Length
  • 305 Meters (1000 ft)
  • Voltage
  • 300V
  • Insulation Material
  • Polyolefin (PO)
  • Application
  • Data, Signal, and Control Cable Installations
  • Conductor Material
  • Bare Copper
  • Jacket Material
  • PVC (Polyvinyl Chloride)
  • Storage Temperature
  • -20°C to +75°C
  • Shield Material
  • Unshielded
  • Jacket Color
  • Gray
  • Material
  • Copper, Polyolefin, PVC
  • Color
  • Gray
  • Size
  • 22 AWG
  • Rip Cord
  • Yes, For Easy Stripping
  • Pairing
  • No (Individual Conductors)
  • Minimum Bend Radius
  • 4.5 Inches
  • Maximum Conductor Resistance
  • 16.5 Ohm/1000ft @ 20°C
  • Maximum Capacitance
  • 53 pF/m
  • Insulation Thickness
  • 0.009 inch (0.23mm)
  • Flame Test
  • UL 910
  • Jacket Thickness
  • 0.015 inch (0.38mm)
 

BELDEN 5304FE Trade Information

  • Minimum Order Quantity
  • 305 Meter
  • Main Domestic Market
  • All India
 

BELDEN 5304FE About

Security & Sound, #18-6c, BC, Shielded, CMR.

Security & Sound Cable, Riser-CMR, 6-18 AWG stranded bare copper conductors with polypropylene insulation, Beldfoil shield and PVC jacket with ripcord.



Engineered for Safety and Performance

The BELDEN 5304FE features UL 910 flame testing and a low-smoke, flexible design, making it a reliable choice for plenum installations where stringent fire safety requirements exist. Its construction ensures dependable performance for security, control, and instrumentation systems.


Easy Installation and Versatility

This cable's rip cord enables effortless jacket removal, streamlining installation and saving valuable time onsite. Flexible materials and a minimum bend radius of 4.5 inches provide adaptability for routing through complex pathways in ceilings and conduits, fitting various indoor settings.


Durable Materials Built to Last

Crafted with solid bare copper conductors, polyolefin insulation, and a durable gray PVC jacket, the BELDEN 5304FE resists both environmental and mechanical stresses. Its UV resistance and robust insulation contribute to longevity and stable performance, even in extended installations.

FAQ's of BELDEN 5304FE:


Q: How is the BELDEN 5304FE cable typically used in building installations?

A: The BELDEN 5304FE is commonly used for data, signal, and low-voltage control applications in fire and security systems, as well as instrumentation installations, particularly in plenum spaces and areas demanding high safety and performance standards.

Q: What benefits does the UL 910 flame test rating provide?

A: The UL 910 rating ensures the cable is flame retardant and produces low smoke, making it suitable for plenum areas where fire safety and air quality are paramount during emergencies.

Q: What makes installation of the BELDEN 5304FE cable easier?

A: With an integrated rip cord for quick jacket stripping and a flexible design with a 4.5-inch minimum bend radius, this cable simplifies routing and handling, speeding up the installation process and reducing labor.

Q: Where can this cable be installed for optimal performance?

A: This cable is plenum rated for use in air handling spaces above ceilings or below floors, typically found in commercial or institutional buildings in India and worldwide.

Q: What is the maximum voltage and temperature rating of the BELDEN 5304FE?

A: The cable is rated for up to 300V and can operate within a temperature range from -20C to +60C, with storage temperatures allowed up to 75C.

Q: Which materials contribute to the cable's durability and flame resistance?

A: BELDEN 5304FE utilizes bare copper conductors, polyolefin insulation, and a robust PVC jacket to achieve its flame retardant, flexible, and durable properties.

Q: Is the cable shielded, and what is its typical signal usage?

A: The BELDEN 5304FE is unshielded and designed for low-voltage signal transmission, control, and data lines where electromagnetic interference interference is minimal or manageable.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Belden Cable Category

Multicore Shielded Cables

Multicore Shielded Cables

Price 44.0 INR / Meter

Minimum Order Quantity : 100

Insulation : PVC insulated, high dielectric strength

Usage & Applications : Industrial control, signal transmission, audio systems, instrumentation, communication, and security installations.

Conductor Type : Stranded

Number of Conductor : 2 to 24 (as per specification)

BELDEN 4694R

BELDEN 4694R

Price 240.0 INR / Meter

Minimum Order Quantity : 305

Insulation : Gasinjected FHDPE

Usage & Applications : Highdefinition broadcast, highfrequency SDI distribution, TV studio cables, field use.

Conductor Type : Solid

Number of Conductor : 1

Belden YJ70879 Cable

Belden YJ70879 Cable

Price 65 INR / Meter

Minimum Order Quantity : 100

Insulation : PVC

Usage & Applications : Industrial Automation, Process Control

Conductor Type : Stranded

Number of Conductor : 7

BELDEN 1192A

BELDEN 1192A

Price 315.0 INR / Meter

Minimum Order Quantity : 100

Insulation : Polyolefin

Usage & Applications : Balanced analog audio circuits, lowlevel signal transmission, studio wiring.

Conductor Type : Solid

Number of Conductor : 2 (1 Pair)



Back to top